Pulsation Analysis For High Pressure Petroleum Pipelines


Objective: Piping systems are a central part of numerous engineering installations. A number of sources such as pumps generate vibrations which can propagate along the pipes and excite other structures. These vibrations can cause two main problems, namely mechanical fatigue and acoustical noises. Further, interaction of the dynamic flow generated by the pump plungers with acoustical resonances in piping systems can result in high pressure pulsation levels pump and piping, cavitation, excessive vibrations and failures. Moreover, higher frequency fluid borne noise can be generated from flow perturbations associated with elbows, valves or cross section changes in the pipe. This design approach in conjunction with pulsation simulation is required to couple technical analysis of piping system to ensure that the piping will have adequate supports and clamps to maintain mechanical natural frequency of major acoustical energy.

Modeling and Analysis: The first design approach involved pulsation and vibration control through the use of good piping layout and support principles, adequate suction pressure and use of pulsation control devices such as dampers, accumulators, preventers, hydraulic isolators, inhibitors, suppressors, stabilizers, acoustic filters and selected piping configurations.The acoustical simulation techniques predict the potential of cavitations and the  required minimum suction to prevent cavitations, based on amplitudes of the pulsations. The results obtained from the analysis proved that the pulsation levels at the suction end were considerably reduced and the pulsation levels were found to be under API 674 standards. Based on the pulsation amplitudes at various frequencies harmonic loads acting on the pipelines were calculated. These harmonic loads were applied at respective nodes and a FEM based harmonic analysis was done to determine the natural frequency of the system and response of the system to harmonic loads arising from pressure pulsations.



Conclusion: From the analysis the pipeline was first tested for the given set of pulsation damping equipments and reciprocating pumps. It was observed that the old configuration did not provide the desired pulsation control in the system. We observed amplification in pulsation in the suction side which was much above the values accepted by API and cavitations were observed at the suction end of the plunger. To reduce the pulsation it was therefore suggested that an additional pressure dampening equipment of size 1 liter must be installed 0.55 m from the suction end of the reciprocating pump. Further the analysis done on the pipeline with the additional dampening accumulator shows considerable reduction in pressure pulsation and the pulsation amplitudes were much below the allowable limits
Categories: Engineering Simulations, Bentley-AutoPIPE, PULS, Pulsation Analysis

Comments

Popular posts from this blog

CFD Analysis Services and CFD Modelling Services

Mechartes focus on providing top quality CFD Analysis & CFD Modelling Services and believe provide to our clients with correct results which too continually delivered on time. Mechartes experienced technical member is well qualified and wide intimate with and use the world’s most advanced CFD software package. Mechartes produced to the foremost advanced and complex CFD simulation techniques to produce real-world engineering solutions that square measure price effective, sensible and commercially viable. We offer the following CFD Analysis services: * POWER, OIL & GAS * BUILDING & CONSTRUCTION * AUTOMOBILE & HIGH TECH * Product Selection Software * IoT based hardware & software development * Engineering Design Tools * Dynamic Mesh Analysis Simulation * Combustion Analysis & Modeling * Heat Transfer Analysis * HVAC Analysis and Design * Hydrodynamic Analysis * Turbomachinery Analysis Advantages of CFD Analysis * Ability to foresee im...
CFD Analysis to Study the Wind and Heat-Island Effect due to Outdoor A.C. Units in a High Rise Building To study the airflow around the project building & other buildings due to the effect of wind and effect of heat generated by outdoor air conditioners installed in high rise project building on other surrounding buildings in worst case scenario. For wind flow analysis the predominant wind direction of SW with average wind velocities of 3 m/sec in Mumbai is considered based on the ISHRAE weather data. Hence, in worst case scenario all 30 floors with 20 outdoor AC units in each floor were considered for total heat dissipation from the project building. The worst case conditions were simulated for 21st March at 22:00 which is assumed to be a condition when all the ACs were working. At that moment as per ISHRAE weather data the ambient temperature in Mumbai is 26.9 C, same was considered in the  CFD analysis . Modelling and Analysis: Based on the provided CAD drawin...